Otis Elevator service tool 16 buttons divided into two parts:

Left part four : MODULE, FUNCTION, SET, Blue key

        
1.MODULE software tools in the service of any place to return to the main menu of the service tool.

        
2.FUNCTION anywhere in the system to return to the installation and maintenance functions menu choice system

        
3.SET anywhere in the function to return to the Project menu for selection installation and maintenance functions

        
Blue key equivalent to computer keyboard on retaining key the SHIFT, (no blue key is the white part of the function of the button, press the blue button is blue part of the function of the button) when press the blue key, you will see to the debugger displays the first character position of a blinking cursor, which represents the blue button to function effectively, when you press the corresponding function key, the blinking cursor will disappear.
Right twelve keys

        
All half white and half blue, normal press is to use the white part of the function, if you want to use the blue part of the function, you need to first press the lower left corner of the keyboard is not marked symbol blue button Then you want to press the function key is pressed. Function with the blue button and the twelve keys on the right computer keyboard above the principle is the same, the blue button on the block is equivalent to computer keyboard key down the SHIFT.

        
FUNCTION key feature

        
SHIFT + 4 hexadecimal number A

        
SHIFT + 5 hexadecimal number B

        
SHIFT + 6 change has any number of input symbols or hexadecimal number C

        
SHIFT + 7 hexadecimal number D

        
SHIFT + 8 hexadecimal number E

        
SHIFT + 9 hexadecimal number F

        
CLEAR to erase the last entered digit (if the input error)

        
SHIFT + CLEAR (this function is equivalent to the ENTER key.) Computer keyboard input or change the values ​​saved

        
GO ON-forward display

       
GO BACK backward conversion display (press the SHIFT key, and then press the GO ON / GO BACK key GO the BACK function will be implemented.

Server uses:

        
ST's first display will show the server into the interface board of the Otis Elevator: SELF TEST-OK-MECS-MODE words here: server self-test passes, the current connection is the the modular elevator control system mode , this display is normal, if other words, set the debugger unplug and then re-inserted in the experiment, if the problem can not be solved, then the debugger or elevator components may appear a failure.