Xi'an YuanQi Elevatorparts Company: schindler elevator parts

Xi'an YuanQi Elevatorparts Company: schindler elevator parts: Schindler Elevator Parts traction drive Schindler elevator parts traction wheel drive components. Schindler Elevator Parts rope suspension ...

schindler elevator parts


Schindler Elevator Parts traction drive Schindler elevator parts traction wheel drive components. Schindler Elevator Parts rope suspension sheave, one end of the suspension cab Schindler Elevator accessories, the other end of the suspension counterweight by Schindler Elevator accessories, wire rope and Schindler elevator parts traction wheel generated by the friction of the traction drive car of the Schindler Elevator accessories for running up and down.
Schindler Elevator Parts traction calculation
Schindler elevator parts traction sheave grooves can produce effective traction is the coefficient of friction between the rope and the sheave groove Schindler Elevator parts and Schindler Elevator accessories the wire rope bypassing Schindler elevator parts traction wheel package The function of the angle.
2. Measures to improve traction Schindler Elevator accessories
change the shape of the rope groove and rope groove material to increase the coefficient of friction.
b increasing the wrap angle
c. increase Schindler Elevator accessories car weight
3. Roping
Schindler elevator parts traction rope roping depends largely on the position of the traction unit, the car of the Schindler Elevator accessories rated load and rated speed conditions. Determine roping should be considered in the selection, has a higher transmission efficiency, reasonable energy consumption, and beneficial to extend the life of the rope Schindler accessories.
Schindler Elevator Parts traction sheave rope groove wear the reasons
Rope life factors affect Schindler Elevator accessories generally also affect the life of the Schindler elevator parts traction wheel, there follows several factors:
a Schindler Elevator Parts traction sheave
b. Schindler Elevator Parts rope structure, material, its physical properties
car running height of c. Schindler Elevator Parts
d. loads
e. Schindler Elevator traction machine accessories and other technical parameters of the components
f. environment and maintenance

2013年3月29日星期五

Xi'an YuanQi Elevatorparts Company: SCHINDLER elevator brake W163

Xi'an YuanQi Elevatorparts Company: SCHINDLER elevator brake W163: Check the brake shoe should fit tightly to the the Schindler Elevator brake  W163  wheel brake surface, when disengaged, the brake shoe sho...

SCHINDLER elevator brake W163


Check the brake shoe should fit tightly to the the Schindler Elevator brake W163 wheel brake surface, when disengaged, the brake shoe should leave Schindler Elevator brakes brake wheel surface without local friction, when a gap formed between the wheel and the brake shoe in the brake braking Schindler shall not be greater than 0.7 mm.
Schindler brake-shaft must be able to automatically rotate and often with a thin oil lubrication, the electromagnet in the job, touch iron should be able to slide freely, without jamming.
Schindler Elevator brake W163 solenoid coil wiring should be no loosening, the coil external short-circuit proof insulation.
Schindler Elevator brakes brake shoe pad if greasy to remove the cleaning, to prevent slipping.
Schindler Elevator brakes brake wheel gap increases when the brake shoe pads wear, the brake is not normal. When abnormality occurs percussion, should be adjusted to the movable core, a nut connected with the brake shoe arm, to compensate for the thickness of the wear out, so that the clearance recovery.
When the brake shoe pad wear value than 2/3 of the liner thickness, should be replaced.
Schindler Elevator brake W163 spring every once in a while to adjust their spring force to lift full load decline should be able to provide sufficient braking force of the car quickly stop bit, full load rises brake can not be too fierce to be smooth from leveling speed the transition to the and accurate stop layer to want to stop floor surface.

2013年3月28日星期四

Xi'an YuanQi Elevatorparts Company: Mitsubishi Elevator PLC

Xi'an YuanQi Elevatorparts Company: Mitsubishi Elevator PLC: Modern industrial production equipment, a large number of digital and analog Mitsubishi elevator control device, for example, the motor st...

Mitsubishi Elevator PLC

  Modern industrial production equipment, a large number of digital and analog Mitsubishi elevator control device, for example, the motor starts and stops, the opening and closing of the solenoid valve, product count, setting of temperature, pressure, flow, and control automatic control problems in the industrial field, a Mitsubishi Elevator programmable controller (PLC) has become one of the most effective tools to solve. PLC control system design should pay attention to the following points.
  Mitsubishi Elevator programmable logic controller (PLC) programming and Mitsubishi Elevator optional: 
  Currently on the market Mitsubishi Elevator PLC control system, in addition to domestic brands, foreign brands: Japan OMRON, MITSUBISHI, FUJI, IDEC, HITACHI, Panasonic, Siemens, Germany, South Korea's LG and so on, how to buy Mitsubishi Elevator PLC control system products?
  1. Optional Mitsubishi Elevator PLC control system programming:
  Mitsubishi Elevator PLC control system programming can be taken in three ways: programming statements with the handheld programmer, of Mitsubishi Elevator PLC control system programming only with manufacturers under the table in the statement. Middle of easy-to-site commissioning and the small size and low cost, but the the Mitsubishi elevator PLC control system programming efficiency is low adapt the model type is more suitable for the system capacity, with less system. The graphics programmer programming, this approach uses a graphical programming, convenient and intuitive, the the general electrician short-term can be applied with ease, but higher prices programmer. Package Programming with IBM and IBM-compatible personal computer + Mitsubishi PLC control system, this way is the most efficient one way, is the most commonly used one, but most of the expensive package.
  Try to use the products of the big companies, because the quality of their products is guaranteed, and good technical support, and after-sales service is also generally better, is conducive to future product expansion and soft and hardware upgrades.
  System should first determine the control of the control system stand-alone system with Mitsubishi Elevator PLC or with Mitsubishi Elevator PLC control system to form a network, and thus calculate the input and output (I / O) points, and in the purchase of the Mitsubishi Elevator PLC control system when the reserve margin of 10% on the basis of the actual needs points.
  Determine load type According to Mitsubishi Elevator PLC control system output of the load carried by DC type or exchanges type, high-current or low current, and Mitsubishi Elevator PLC control system output frequency of the action etc., which determine the output using relay output or transistor output or thyristor output. The different load selection of different output mode of the stable operation of the system is very important.
  Storage capacity with the instruction execution speed is an important indicator of the PLC selection, the greater the amount of general storage, faster PLC the higher prices, foreign manufacturers products are much the same, but also have some differences.
  6. "COM" point selection,
  Different PLC product, the "COM" number of points is not the same, some a "COM" points with eight output points, some with four output points, also with one or two output points. When the load of many kinds and large current, a "COM" output points with a 1-2 point less number of load type for a long time, the use of a "COM" point with 4-8 output point.
  Manufacturers developed different software focus systematically compatibility when purchasing, yet did not find completely compatible products, the product should be based on a systematic and rational choice Mitsubishi Elevator PLC control system.
  Second, the expansion module optional
  For small systems, such as the 80 points within the system, generally do not need to be extended; When the system is large, it is necessary expansion. Products of different companies, the system is the total number of points and the number of expansion modules have a limit, when the expansion still can not meet the needs, can be a network structure. Individual instructions of the same time, some manufacturers do not support expansion modules, therefore, to pay attention during the software programming. When the temperature analog modules, the manufacturers also have some of the provisions, see related technical manuals.
  Mitsubishi Elevator PLC control system network design
  Mitsubishi Elevator PLC control system network design, its difficulty is much greater than the PLC stand-alone control, she was more familiar with the models should be used first, have a more in-depth understanding of their basic instruction and function of instruction, and the instruction execution speed and user program storage capacity should also be careful to understand. Otherwise can not meet the real-time requirements, resulting in a system crash. In addition to the communication interface, the communication protocol, the data transmission rate must be considered.
  Finally, to Mitsubishi Elevator PLC control system manufacturers to seek network design and software support and detailed technical information, As for the selection of several layers of workstations, in accordance with the size of the system.
  Fourth, the software development
  Selected Mitsubishi Elevator PLC control system product specification before in preparation software, you should first become familiar with, and to be familiar with and then programming. The use of graphical programming package programming, can be programmed directly, handheld programmer programming should draw ladder, then programming, so you can reduce errors, speed is also fast compiled completed after the first air operation until each action is normal, and then debugging on the device.
  1 power circuit
  Mitsubishi Elevator PLC control system powered AC85-240V (DC24V) to adapt to a wide power range, but for anti-jamming, power-purifying element (such as the power supply filter, 1:1 isolation transformer should be retrofitted)
  Mitsubishi Elevator PLC control system DC24V power use
  Each company Mitsubishi Elevator PLC control system products generally have DC24V power, but the power supply capacity is small, for tens of milliamps to several hundred milliamps, should pay attention to use it with a load capacity, at the same time do a good job against short circuit measures (because overload or short-circuit of the power supply will affect the run of the of Mitsubishi Elevator PLC control system).
  3 external DC24V power 
  If the input circuit the DC24V power proximity switches, photoelectric switches, etc., and not enough the DC24V power capacity Mitsubishi Elevator PLC control system, from external DC24V power; but the power of the "not" end with the PLC DC24V power "and" COM "terminals connected, otherwise it will affect the run of the of Mitsubishi Elevator PLC control system. 
  4. Input sensitivity
  Manufacturers of of Mitsubishi Elevator PLC control system input voltage and current regulations, when the maximum input current or leakage current of the input element of the input current is greater than the Mitsubishi PLC control system, there will be a malfunction, reducing sensitivity. So shall apply the weak current input and leakage current to take protective measures, and the selection of the input for sink input Mitsubishi Elevator PLC control system.
  Two-wire sensor (photoelectric switches, non-contact switch) LED limit switch input leakage current will generate input error or lights countermeasures bleeder resistor to reduce the input impedance for the connection resistance deduced from Figure 1 in the formula:
  Transistor or triac output, received a greater impact on current equipment, it is necessary to consider the protection transistor and thyristor. The transistor and the thyristor can withstand the impact of current of 10 times the rated current, if exceeded, according to Figure 2, one of the Figure 3 to reduce it:
  5. Inductive load handling
  Input and output termination inductive load, surge suppressors or diode in parallel across the load a pole side of the cathode of the diode voltage (x) is connected.
  6 external interlock with ground
  Mitsubishi PLC control system to control the motor reversing, causing accidents and mechanical damage, should form a chain in the external loop counter-action, to avoid abnormal operation of the PC. 
  Ground: GR terminal earth ground terminal. Used to prevent the induction of dedicated ground wire (cross-sectional area of 2mm2 wire) and a third grounding method (grounding resistance of 100Ω or less).
  LG is the noise filter neutral terminal, a malfunction due to noise, or in order to prevent electric shock, LG and GR shorted, the third ground. The length of the ground line is preferably within 20m.
  The ground wire with other devices sharing or connection with the metal structure of the building will be counterproductive, adversely affecting.
  7 Mitsubishi Elevator PLC control system external drive circuit
  Mitsubishi Elevator PLC control system output can not directly drive the load must be used in the external drive circuit can be driven with a solid-state relay or thyristor circuit, and should be used to protect the circuit and surge absorption circuit.

2013年3月26日星期二

Xi'an YuanQi Elevatorparts Company: Thyssen Elevator Inverter CPIK15M1

Xi'an YuanQi Elevatorparts Company: Thyssen Elevator Inverter CPIK15M1: Thyssen Elevator Inverter CPIK15M1 unique field, automatic torque boost function in the elevator drag to get good comfort and stability. Acc...

Thyssen Elevator Inverter CPIK15M1

Thyssen Elevator Inverter CPIK15M1 unique field, automatic torque boost function in the elevator drag to get good comfort and stability. Acceptable controller such as a PLC multi-speed frequency command or analog voltage, current command; through self learning to adapt to a variety of motor and get a good vector control characteristics; low speed the excellent smooth start; hardware reliability and highly cost-effective .
  The basic principle of the VVVF type elevator
  According to the motor theory, the AC motor speed formula:
  n = 60f (1-s) / p
  In the above formula: f is the power supply frequency of the stator; p is the number of pole pairs;
  s is the slip; n is speed.
  Therefore, the AC motor speed control method following:
 (1) to change the motor pole number p, the motor speed can be changed. AC double-speed ladder governor.
 (2) is changed by adjusting the size of the stator winding voltage to the slip s, in order to achieve the speed control purposes. AC variable speed ladder governor.
 (3) changing the the stator power frequency f can also achieve speed control purposes, but f not exceed the maximum rated motor frequency. Elevator as a constant torque load speed in order to maintain maximum torque unchanged, according to the torque formula the M = CmФIcosφ in Cm motor constant, I is the rotor current, Ф for the motor air gap flux, cosφ rotor power factor. Must remain the Ф constant, again based on the voltage equation U = 4.44fWkФ, where U is the stator voltage, f is the frequency of the stator voltage, W of stator winding turns, k is the motor constant, must maintain the U / f is constant, i.e. Thyssen Elevator VVVF inverter must both two functions referred to as the VVVF (Vary Voltage Vary Frequency) type Thyssen inverter, which is the basic control principle VVVF elevator.
  Select power and other accessories
  Usually the Thyssen drive in an elevator application also need the brake unit with the braking resistor, to obtain a sufficient braking torque during the regeneration state; also need to configure the the PG speed card encoder the speed feedback signal; generator operation in the long term and other special places also need to configure the AC reactor. ThyssenKrupp Elevator the inverter generally in accordance with the motor power amplifier with a choice, in order to Thyssen inverter control performance, general the Thyssen Elevator Inverter CPIK15M1 power shall satisfy the following formula:
  The Thyssen Elevator Inverter CPIK15M1 power ≥ K × 1.732 × Vm × Im
  Which current waveform correction coefficient, K, Vm rated motor voltage, Im is the motor rated current.
  The choice of the brake unit
  The Thyssen Elevator Inverter CPIK15M1 applications when rising car no-load or reload decline, the drag system exists potential load decentralization. The motor will be in the running state of regenerative braking energy flow to the DC link by the inverter link in parallel diode to charge the filter capacitor motor feedback. When the feedback energy is large, it will cause the DC link voltage rises failure, motor rapid deceleration will cause the above phenomenon.
  The solution is the Thyssen Elevator Inverter CPIK15M1 DC link shunt braking unit and braking resistor. The braking unit is an optional component of the Thyssen drive, equipped to detect and control circuit, its work Thyssen inverter DC link voltage line detection. When the voltage exceeds the allowable value set, the trigger brake transistor is turned on, the release of energy through the resistor to maintain Thyssen Elevator Inverter CPIK15M1 DC bus voltage within the normal operating range, a braking unit several resistors in parallel, as the conditions .
  Resistor selection
  Resistor selection is very important, resistor selection is too large braking torque resistance is chosen too small too much current, resistance heating, and other issues are difficult to resolve. General power of resistance and resistance we recommend lifting height larger, higher motor speed can be properly reduced resistance to higher braking torque, the minimum can not meet the braking torque, to be replaced a power Thyssen inverter.
  Braking unit and braking resistor selection should be based on the feedback of the largest energy and time. The general braking resistor should be chosen so the brake current Is not exceed the Thyssen drive rated current Ie, the maximum power of the braking resistor Pmax is less than 1.5 times the Thyssen Elevator Inverter CPIK15M1 power, then multiplied by the overload factor . Overload factor related to the deceleration time and continuous braking time specific to the manufacturers to provide resistance overload factor and parameter sample.
  The using braking resistor consumption motor regenerative braking energy back to the DC circuit, Thyssen inverter manufacturers usually provide the user optional - braking unit and braking resistor. The braking process, when the circuit DC voltage is higher than the normal voltage of 70V, the IGBT in the brake unit, the DC chopper, so that the braking resistor current flowing through the regenerative power consumption.
  PG Card
  PG card generally select PG-B2, only encoder line encoder pulse output or need 2000p / r PG-X2 speed card frequency output can provide a maximum of 32 points available for the controller count.
  Optical encoder
  Use incremental 600p / r, push-pull amplifier output A phase B phase Z relative to the origin of the signal, shaft diameter 8mm hollow encoder.
  System components
  A hardware configuration of the system shown in Figure 1, is constituted mainly by the following parts:
  iAStar Elevator Thyssen Elevator Inverter CPIK15M1 can achieve smooth operation and precise control of the motor to achieve the desired output. And PG, U / f control, vector control without PG, PG U / f control, PG vector control, four control integration, which PG vector control is the most suitable elevator control requirements. The capacity options best freshman magnitude optional, elevator motors general election llkW or 15kW asynchronous motor. 11kW motor election 15kW inverter Thyssen the 15kW motor elect 18kW inverter Thyssen.
  Thyssen inverter parameter settings
  As a result of the PLC logic control components, so the the Thyssen Elevator Inverter CPIK15M1 and PLC communication when using switch instead of analog. Here are a few main parameters settings: In order to reduce the start-impact and increase passenger comfort, speed loop speed control system should be proportional coefficient smaller integration time constant should be larger C5-01 = 5 was chosen , C5-02 = 2s. In order to improve operational efficiency, the express train frequency should be selected as the power frequency, and crawling frequency as low as possible to minimize the impact of parking Dl-02 = 50Hz was chosen Dl-= 5Hz.
  Overhaul the slow frequency optional Dl-09 = 12Hz. While "S" curve characteristic prevents the start of the vibration generated when the change speed or stop, which is most applicable in the elevator, can greatly improve the ride comfort. In addition, fault diagnosis, detection, memory and other functions of the Thyssen Elevator Inverter CPIK15M1 system maintenance is also very convenient and practical. In order to ensure the accuracy and reliability of operation of flat layers, the traction motor speed control should be a closed loop, its rotational speed detected by the motor coaxial rotation of the rotary encoder is complete. Must ensure that the concentricity and reliability of the connection of the rotary encoder and the electric motor, in order to ensure the accuracy of the speed sampling. Thyssen inverter other commonly used parameters can be entered directly under the grid voltage and motor nameplate parameters. Elevator operation ideal curve shown in Figure 2.
  Thyssen Elevator Inverter CPIK15M1 work in the best condition, after the completion of the parameter settings, you need to make the Thyssen inverter motor driven self-learning: traction mechanism drive wheels and the motor shaft from the The motor is unloaded, and then start the motor, the the Thyssen Elevator Inverter CPIK15M1 can automatically identify and store the relevant parameters of the motor, Thyssen inverter optimal control of the motor. At this point, the Thyssen Elevator Inverter CPIK15M1 parameters are set.

2013年3月25日星期一

Xi'an YuanQi Elevatorparts Company: The advantage of permanent magnet synchronous trac...

Xi'an YuanQi Elevatorparts Company: The advantage of permanent magnet synchronous trac...: (1) low wear. traction machine  for elevators , the biggest advantage is that there is no transmission structure, in addition to the rotor ...

The advantage of permanent magnet synchronous traction machines for elevators


(1) low wear. traction machine for elevators, the biggest advantage is that there is no transmission structure, in addition to the rotor shaft (it is also a traction axis) on a set of bearings, never any mechanical wear, no wear and tear, the natural extension of the drag lead the life of the machine. (2) energy-saving. The gearless traction machine because there is no transmission structure, there is no mechanical power loss, relatively speaking, it saves energy and running expenses. Load 1000kg elevator speed of 1.00m / s VVVF elevators, for example: OTIS gear traction machine (the traction ratio 1:1) need to 11kW; Weber gearless machine (traction ratio of 2:1) Just 6.7kW. (3) ease of installation. Drag wheel is fixed directly to the shaft of the motor, compact structure and small size, light weight, ease of lifting and transportation, on-site installation will be easier and more still load 1000kg, elevator speed 1.00m / s VVVF elevators, for example:OTIS gear traction machine 17CT, weight 1300kg; Weber gearless machine the WEB-1.0-1000, weight 300kg. (4) running smoothly. The absence of transmission structure, there is no belt drive lost turn, slip, elevator leveling of high precision, reliable operation; there is no gear noise and vibration, and thus the performance of the lift running smoothly, low noise, which is Elevator green revolution the salient features. (5) fuel efficient. Gearless traction machine Since no transmission structure, it eliminates the need for traditional deceleration box lubricants, only a sufficient amount of grease in the bearing memory. Daily lubrication replacement cumbersome Maintenance does not exist, and also to avoid the pollution lubricant leakage and maintenance difficulty, but also saves the lubricating oil costs. (6) is easy to use. Gearless traction machine for elevators with no liquid lubricants, there is no leak, not only there is no pollution, and can be any gesture installation, such as bottom-up hanging at the roof of the hoistway.

2013年3月24日星期日

Xi'an YuanQi Elevatorparts Company: The fault of OTIS elevator pcb RCB-II

Xi'an YuanQi Elevatorparts Company: The fault of OTIS elevator pcb RCB-II: 1. An elevator at runtime to not open the door of the flat layer, MCB board DIF lamp is not lit, replace the MCB board . 2.  Elevator Expre...

The fault of OTIS elevator pcb RCB-II


1.An elevator at runtime to not open the door of the flat layer, MCB board DIF lamp is not lit, replace the MCB board.
2. Elevator Express uplink normal, Parking Express under the parking not flat layer (just start) to replace the MCB board.
3. Elevator after closing is not running, the inside of the door panels minor relay sound, MCB board of DIF indicator does not light, the the door machine communication signal is lost, the replacement of the MCB board. 
4. RCB-II board no lights, the MCB board OCF lights, unplug and RCB-II communications, OCF lamp has been lit, the power supply is normal, J5 normal power source, RCB-II board J2 normal, replace the RCB-II board MCB. 
5. RCB2 board is powered, all outbound calls does not work, replace it. 
6. Elevator outgoing call display highest downlink arrows, replace RCB2 board. 
7. Elevator no display, the directive can not be registered. GL1 lights RCB2 panel does not light a 8.1 replace RCB2 board, check the thermal circuit, such as thermal circuit barrier, MCSS digital tube display a three-phase poor contact phenomenon of O 2, check the motor, such as poor inverter CURREUT FEEDBACK error (including the UDX contact) check motor three-phase insulation, if you have any questions, inverter CURRENT FEEDBACK SUM error check MCSS DBSS chip if there is poor contact phenomenon 5, DBSS internal failure. 
9.The elevator car Dashboard the COP layer selection signal is not registered, the driver Elevator normal, replace the MCB board after normal. 
10. DBD loop barrier: DBD the loop static when barrier, the elevator the MCSS display 0, for example, C relay normally closed contact does not make sense.

2013年3月21日星期四

Xi'an YuanQi Elevatorparts Company: Working Principle of elevator safety light curtain...

Xi'an YuanQi Elevatorparts Company: Working Principle of elevator safety light curtain...: Elevator safety light curtain system is a newly developed set before the light curtain technology and price of the director of the manufact...

Working Principle of elevator safety light curtain


Elevator safety light curtain system is a newly developed set before the light curtain technology and price of the director of the manufacturers of high quality automatic control products, the use of the infrared scanning probe technology. Transmitting means and receiving means mounted on both sides, the internal microcontroller and a microprocessor controlled digital program, so that the infrared transceiver unit is formed in the high speed scanning mode, the infrared light curtain guard barrier, when people and objects into the light curtain barrier region, The control system quick conversion output level signal, so that the load operation, when the purpose of the people and objects leaving a light curtain guard zone, the load normally closed automatically, so as to achieve secure. Practical application of elevator safety light curtain controller is not required, only a transmitter and receiver, used by air plug socket or cable connection, the output can be directly the external various types of computer digital interface.
As shown in the figure is a safety light curtain detects an object (such as the hand) to enter the test schematic structure diagram. The figure, one side of the light curtain equidistantly mounted a plurality of infrared emission tube, the other side corresponding to the same number of the same ordered infrared receiver, an infrared-emitting tube corresponds with a corresponding infrared receiver, and is installed in the same a straight line. When the infrared emission control on the same line, there are no obstructions between the infrared receiver, infrared emission tube emitted modulated signal (light signal) can reach the infrared receiver. Infrared receiver to the modulation signal is received, the corresponding internal circuit outputs a low level, while in the case of obstacles, the infrared emission tube issued by the modulated signal (light signal) does not successfully reach the infrared receiver tube, then the infrared receiver The tube does not receive a modulation signal, the corresponding internal circuit output is high. When no object through the light curtain, all infrared emission tube issuing a modulated signal (light signal) can successfully reach the corresponding infrared receiver of the other side of the tube, so that all internal circuits output low. Thus, by analysis of the state of the internal circuit can detect the presence or absence of the information of the object.
Infrared transmitter and receiver of the safety light curtain path number theoretical maximum of 215, taking into account the spacing between the actual light curtain height and the vertical passage, and generally not more than 48.

2013年3月20日星期三

Elevator door machine

Xi'an YuanQi Elevatorparts Company: Mitsubishi elevator PLC

Xi'an YuanQi Elevatorparts Company: Mitsubishi elevator PLC: Programmable controller are a stored program controlled device, the control function is achieved through the program stored in the memory, T...

Mitsubishi elevator PLC

Programmable controller are a stored program controlled device, the control function is achieved through the program stored in the memory, To make changes to the control function, in large part only need to change the software instructions can beso that the hardware and software technology. Increasing its position in industrial control, occupies an extremely important position, the most important reason is that it has the following unique characteristics of high reliability, easy to learn programming versatility, the system design cycle is short, the production process change adaptable, simple installation, commissioning, maintenance workload and adapt to the industrial environment. In short, the elevator control more complex, the use of programmable controllers for elevator control a vast space. mitsubishi elevator PLC is designed specifically for industrial process control equipment, with the application of mitsubishi elevator PLC technology continues to evolve, will make its volume greatly reduced, function continuously improved process control more stable and reliable. Strong anti-jamming performance, mechanical and electrical components organically combined in one device, instrumentation,electronics and computer functions combined. Therefore, it has become a key technology in the elevator running.

2013年3月19日星期二

Xi'an YuanQi Elevatorparts Company: KONE elevator pcb LCE-KNX KM713130GO1

Xi'an YuanQi Elevatorparts Company: KONE elevator pcb LCE-KNX KM713130GO1: LCE-KNX unlock steps Elevator Model: KONE 3000 MiniSpace Control system: LCE-KNX KM713130GO1 Reason: KONE 3000 MonoSpace elevator run of ...

KONE elevator pcb LCE-KNX KM713130GO1

LCE-KNX unlock steps

Elevator Model: KONE 3000 MiniSpace

Control system: LCE-KNX KM713130GO1

Reason: KONE 3000 MonoSpace elevator run of 10,000 and above ,375-LCE-KNX

On the operation buttons are locked can not operate (in addition to selected within and outside the callback function), which will lead to
System parameters can not be set and change.

Objective: To unlock method to restore the normal function of the operation buttons on the 375-LCEEPU and run times

Number is reset to zero.


The electronic board :375-LCE-KNX method has been locked


1, 270 switch hit overhaul mode off the elevator main power


2, pull out LCE-KNX KM713130GO1 on D8 position NVRAM, replace a new NARAM


3, turn on the power


4 operation on LCEEPU button to enter the menu 1-99, the parameter is set to 2. Now


System parameters will revert to the EPROM default value (to do this operation, the elevator must be stopped at the end of


Layer, 77U, 61U must be valid)


5, operation on LCE-KNX KM713130GO1 button to enter the menu 5-7, the parameter is set to 1. Now


The elevator download (LON protocol elevator must be stopped at the bottom, 61U effective)


6, after the completion of the above steps must set the elevator hoistway self-learning. The elevator stopped at the bottom of


(61U), by operating on LCE-KNX button to enter the menu 5-2, the parameter settings


1, 270 after the switch to its normal position


7, LCE-KNX electronic board will beep twice


8, twice after the elevators will slow hoistway self-learning, until the top-level and more than the top floor flat layer


Position after parking, after the leveling position to return to the top level at LCE-KNX digital tube flashes about


Two seconds, and the beep indicates completion of the self-learning, LCE-KNX digital tube will be displayed at this time


Elevator floor (the floor number of floors for the elevator in the system, may be different from the actual number of floors,


Single floors over five meters in height, the the false floors need to set this in the setup menu.


Floors will play a role in the flag before setting these parameters, need to know that between the two layers
False floor)


9, after the learning is complete, the hit 270 switch maintenance position, the start parameter settings. Must be set


Parameters including menu elevator parameters, 3 floors flag. Specific settings based on the scene actual situation


Condition.
10, the parameters are set, the system must be powered off, wait for all the lights off, sending

2013年3月4日星期一

Elevator lock and Elevator door lock


On every landing door and car door has a door electrical interlock contacts only when the sector-wide closed door electrical interlock linking point is closed, the door lock relay JMS pull the elevator to run.
The coupe and sedan are equipped with inspection switch and maintenance switch to overhaul bit the maintenance relay JM pull the elevator is inspected.
In the following four states, brake coil is energized, the brake open:
(1) Express upstream, that is, S , K .
(2) Express downlink, ie X , K .
(3) slow uplink, namely S ↑ .
(4) slow down, that is, X ↑ .
When the elevator starts to run, since the 1A, 2A is not yet energized, their normally closed contacts the RZ1 shorted, so DZZ able to 110V DC voltage, after a period of time after the elevator start delay, 1A energized, the resistor the RZ1 series to DZZ coil, DZZ ends voltage dropped to about 70V, called the sustain voltage. The role of the capacitor C8 is misoperation due to the the DZZ reduced from 110V voltage to the sustain voltage when there is a transition process, prevent DZZ voltage transients. Resistor RZ2 constituting the DZZ the discharge circuit.
In order to prevent the elevator from Express K converted to idle M, DZZ a power of the moment, so into the JK-delay relay, thus ensuring the operation of the brake does not occur twice.
When the elevator up contactor S or downstream contactor X suck timely to run relay JYT pull said elevator being run.
Acceleration and deceleration delay relay
When drivers press the button to start closing through of JYT 1JQ, so J1SA pull when through R1SA to capacitance C1SA charge when the elevator began to run, JYT , J1SA did not immediately release, C1SA by R1SA of J1SA discharge , to make J1SA still suck together for some time, so J1SA delay the release of the relay. When released J1SA, an accelerated contactor 1A pull the elevator start after the buck to an accelerated into steady speed express train state (see run loop).
Elevator in the express run state, J2SA, J3SA, J4SA in suction engagement state, once transferred the slow M ↑ → J2SA delayed release → 2A ↑ → J3SA delayed release → 3A ↑ → J4SA delayed release . 4A now ↑ the formation of 1, 2, 3 deceleration.

2013年3月3日星期日

Xi'an YuanQi Elevatorparts Company: LG Elevator pcb DCD-230

Xi'an YuanQi Elevatorparts Company: LG Elevator pcb DCD-230: LG Elevator  pcb  DCD-230 is dealing mainly with the elevator shaft, the car, the control screen signal input and output. Level conversion,...

LG Elevator pcb DCD-230


LG Elevator pcb DCD-230 is dealing mainly with the elevator shaft, the car, the control screen signal input and output. Level conversion, logical combinations of various signals after the completion of the board, and then sent to the motherboard INV-MPU. INV-MPU output signal of the completion of the logic through the plate, power amplification, and then driving the various display, relays, contactors, and other external devices. The board can be roughly divided into three parts to introduce one. The external input signal is sent LG Elevator pcb DCD-230, after processing the external input signal is sent to the INV-MPU can be divided into two parts, generally external input signal (such as from the hoistway, the control panel, a car) and hall call input signal.(1). Usually an external input signal processing circuit (Figure 1) that the part of the main function of I48A (8-block input buffer), LS138 address decoder, LS240 output driver chip. I48A is a block of a hybrid type integrated circuit, the input is 48V, and the output is TTL level, only elected when the communication number is valid, the the I48A input buffer the input signal can be transmitted to its output, the strobe is invalid the I48A output in a high-impedance status. So the output of the 8 the I48A input buffer can be hung on an output line, the same time only a I48A is selected, and by LS240 the output drive signal to the INV-MPU.