Working Principle of elevator safety light curtain


Elevator safety light curtain system is a newly developed set before the light curtain technology and price of the director of the manufacturers of high quality automatic control products, the use of the infrared scanning probe technology. Transmitting means and receiving means mounted on both sides, the internal microcontroller and a microprocessor controlled digital program, so that the infrared transceiver unit is formed in the high speed scanning mode, the infrared light curtain guard barrier, when people and objects into the light curtain barrier region, The control system quick conversion output level signal, so that the load operation, when the purpose of the people and objects leaving a light curtain guard zone, the load normally closed automatically, so as to achieve secure. Practical application of elevator safety light curtain controller is not required, only a transmitter and receiver, used by air plug socket or cable connection, the output can be directly the external various types of computer digital interface.
As shown in the figure is a safety light curtain detects an object (such as the hand) to enter the test schematic structure diagram. The figure, one side of the light curtain equidistantly mounted a plurality of infrared emission tube, the other side corresponding to the same number of the same ordered infrared receiver, an infrared-emitting tube corresponds with a corresponding infrared receiver, and is installed in the same a straight line. When the infrared emission control on the same line, there are no obstructions between the infrared receiver, infrared emission tube emitted modulated signal (light signal) can reach the infrared receiver. Infrared receiver to the modulation signal is received, the corresponding internal circuit outputs a low level, while in the case of obstacles, the infrared emission tube issued by the modulated signal (light signal) does not successfully reach the infrared receiver tube, then the infrared receiver The tube does not receive a modulation signal, the corresponding internal circuit output is high. When no object through the light curtain, all infrared emission tube issuing a modulated signal (light signal) can successfully reach the corresponding infrared receiver of the other side of the tube, so that all internal circuits output low. Thus, by analysis of the state of the internal circuit can detect the presence or absence of the information of the object.
Infrared transmitter and receiver of the safety light curtain path number theoretical maximum of 215, taking into account the spacing between the actual light curtain height and the vertical passage, and generally not more than 48.

没有评论:

发表评论