2013年3月19日星期二

KONE elevator pcb LCE-KNX KM713130GO1

LCE-KNX unlock steps

Elevator Model: KONE 3000 MiniSpace

Control system: LCE-KNX KM713130GO1

Reason: KONE 3000 MonoSpace elevator run of 10,000 and above ,375-LCE-KNX

On the operation buttons are locked can not operate (in addition to selected within and outside the callback function), which will lead to
System parameters can not be set and change.

Objective: To unlock method to restore the normal function of the operation buttons on the 375-LCEEPU and run times

Number is reset to zero.


The electronic board :375-LCE-KNX method has been locked


1, 270 switch hit overhaul mode off the elevator main power


2, pull out LCE-KNX KM713130GO1 on D8 position NVRAM, replace a new NARAM


3, turn on the power


4 operation on LCEEPU button to enter the menu 1-99, the parameter is set to 2. Now


System parameters will revert to the EPROM default value (to do this operation, the elevator must be stopped at the end of


Layer, 77U, 61U must be valid)


5, operation on LCE-KNX KM713130GO1 button to enter the menu 5-7, the parameter is set to 1. Now


The elevator download (LON protocol elevator must be stopped at the bottom, 61U effective)


6, after the completion of the above steps must set the elevator hoistway self-learning. The elevator stopped at the bottom of


(61U), by operating on LCE-KNX button to enter the menu 5-2, the parameter settings


1, 270 after the switch to its normal position


7, LCE-KNX electronic board will beep twice


8, twice after the elevators will slow hoistway self-learning, until the top-level and more than the top floor flat layer


Position after parking, after the leveling position to return to the top level at LCE-KNX digital tube flashes about


Two seconds, and the beep indicates completion of the self-learning, LCE-KNX digital tube will be displayed at this time


Elevator floor (the floor number of floors for the elevator in the system, may be different from the actual number of floors,


Single floors over five meters in height, the the false floors need to set this in the setup menu.


Floors will play a role in the flag before setting these parameters, need to know that between the two layers
False floor)


9, after the learning is complete, the hit 270 switch maintenance position, the start parameter settings. Must be set


Parameters including menu elevator parameters, 3 floors flag. Specific settings based on the scene actual situation


Condition.
10, the parameters are set, the system must be powered off, wait for all the lights off, sending

没有评论:

发表评论