The fault of OTIS elevator pcb RCB-II


1.An elevator at runtime to not open the door of the flat layer, MCB board DIF lamp is not lit, replace the MCB board.
2. Elevator Express uplink normal, Parking Express under the parking not flat layer (just start) to replace the MCB board.
3. Elevator after closing is not running, the inside of the door panels minor relay sound, MCB board of DIF indicator does not light, the the door machine communication signal is lost, the replacement of the MCB board. 
4. RCB-II board no lights, the MCB board OCF lights, unplug and RCB-II communications, OCF lamp has been lit, the power supply is normal, J5 normal power source, RCB-II board J2 normal, replace the RCB-II board MCB. 
5. RCB2 board is powered, all outbound calls does not work, replace it. 
6. Elevator outgoing call display highest downlink arrows, replace RCB2 board. 
7. Elevator no display, the directive can not be registered. GL1 lights RCB2 panel does not light a 8.1 replace RCB2 board, check the thermal circuit, such as thermal circuit barrier, MCSS digital tube display a three-phase poor contact phenomenon of O 2, check the motor, such as poor inverter CURREUT FEEDBACK error (including the UDX contact) check motor three-phase insulation, if you have any questions, inverter CURRENT FEEDBACK SUM error check MCSS DBSS chip if there is poor contact phenomenon 5, DBSS internal failure. 
9.The elevator car Dashboard the COP layer selection signal is not registered, the driver Elevator normal, replace the MCB board after normal. 
10. DBD loop barrier: DBD the loop static when barrier, the elevator the MCSS display 0, for example, C relay normally closed contact does not make sense.